Contrast Injector Service & Repair — Medrad Stellant & Spectris Solaris
FDM Enterprises provides expert contrast injector service and repair for Medrad Stellant and Spectris Solaris systems. Our field technicians deliver on-site contrast injector repair, preventive maintenance, calibration verification, error code diagnostics, and troubleshooting for CT and MRI imaging departments across the central and southeastern US.
Contrast injectors are mission-critical components in modern imaging workflows. When a Stellant or Spectris Solaris system goes down, exams stop and patient schedules back up. FDM Enterprises responds quickly with the diagnostic expertise to identify the issue and the field experience to resolve it — minimizing downtime and keeping your imaging department running.
Call FDM Enterprises at (615) 479-5572 for fast, expert service.
Stellant CT Contrast Injector Service
Preventive maintenance, error code diagnostics, syringe detection troubleshooting, calibration verification, and repair for Medrad Stellant contrast injector systems used with GE and Siemens CT scanners.
Spectris Solaris MRI Contrast Injector Service
Preventive maintenance, error code diagnostics, syringe detection troubleshooting, calibration verification, and repair for Spectris Solaris contrast injector systems used with GE, Siemens, and Philips MRI scanners.
Preventive Maintenance Programs
Scheduled PM programs for both Stellant and Spectris Solaris injectors — including fluid path inspection, pressure testing, software verification, and component replacement before failures occur.
Emergency Injector Repair
When your injector system goes down unexpectedly, FDM Enterprises provides on-site emergency diagnostics and repair. We carry common replacement parts and have the experience to get your system back online fast.
Faults That Stop A Study
Stellant & Spectris Solaris Faults We Are Called Out To Most
These are the failures that take a contrast injector out of service in a working imaging department. Every one of them is something we resolve on-site. If you are looking at a specific numbered code, see our Stellant error code reference.
Faults That Creep Up On You
Stellant & Spectris Solaris Faults We Are Called Out To Most
These are the failures that take a contrast injector out of service in a working imaging department. Every one of them is something we resolve on-site. If you are looking at a specific numbered code, see our Stellant error code reference.
Our Contrast Injector Services
Frequently Asked Questions
The injector cannot confirm what is loaded, so it refuses to arm and contrast-enhanced studies stop. Stellant reports this as Invalid Syringe or error 867, and it is the most common reason imaging departments call us for injector service. FDM Enterprises diagnoses and repairs syringe detection faults on-site. Call 615-479-5572.
When settings that have run for months start aborting on over-pressure, the injector needs to be tested and its calibration verified. Stellant reports this as error 1010. Lowering the flow rate to keep working quietly changes the study being delivered, so it is not a fix. FDM Enterprises resolves pressure faults on-site and documents the calibration.
Repeated air detection alarms on a visibly clear syringe and tubing mean the detection system needs service. Stellant reports this as error 1022. Disabling the alarm to keep the room running removes a patient safety interlock and is not an acceptable workaround. FDM Enterprises repairs air detection faults on-site.
Most injector faults are repaired on-site at component level. Shipping a head out is rarely necessary and costs days of downtime. FDM Enterprises carries common parts to the visit and confirms the system runs a full clinical protocol before leaving.
Every 12 months for most departments, and more often for high-volume sites running dozens of contrast-enhanced exams a day. PM should include calibration verification on flow rate, volume and pressure, with documentation left on site. Deferred PM shows up later as pressure faults, air detection alarms and mid-case shutdowns. FDM Enterprises schedules injector PM across eleven states.
Yes. Solaris faults that appear only inside the scan room need someone who services both the injector and the MRI system to separate the two. FDM Enterprises services both and resolves these on-site.
FDM Enterprises provides on-site contrast injector service across eleven states: Tennessee, Kentucky, Alabama, Georgia, Florida, Indiana, Missouri, Mississippi, Ohio, North Carolina and South Carolina. Call 615-479-5572 to discuss service in your area.
No. FDM Enterprises is an independent service organisation with 25+ years of field experience on Medrad Stellant and Spectris Solaris systems. Facilities use us for preventive maintenance, calibration verification and component-level repair without an OEM service contract.