{"title":"Injector Consumables","description":"\u003cp\u003eEverything that goes into a contrast injector between services: replacement syringe kits for Medrad, Bracco and Mallinckrodt Guerbet, and the universal tubing, Y-line sets and transfer sets that work across brands.\u003c\/p\u003e\u003cp\u003eSyringe kits are drop-shipped direct to your site. Tubing and transfer sets are sold by the case of 200 with shipping included to the continental United States. If you are not certain which kit fits your injector, send us the model and we will confirm it before you order.\u003c\/p\u003e","products":[{"product_id":"stellant-dual-syringe-kit-case-of-20","title":"Syringe Kit for Medrad Stellant Dual CT Injector - 2 x 200 mL, Case of 20","description":"\u003cp\u003eDual 200 mL contrast syringe kits for the Bayer Medrad Stellant CT injector, Stellant D and Stellant Sx. Replaces OEM part numbers \u003cstrong\u003eSDS-CTP-SPK\u003c\/strong\u003e, \u003cstrong\u003eSDS-CTP-QFT\u003c\/strong\u003e and \u003cstrong\u003eSDS-CTP-SCS\u003c\/strong\u003e. Sold by the case of 20.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injector named above and replace the OEM part numbers listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 x 200 mL syringes\u003c\/li\u003e\n\u003cli\u003e1 x 60 inch T-connector with two check valves\u003c\/li\u003e\n\u003cli\u003e1 x prime tube\u003c\/li\u003e\n\u003cli\u003e2 x spikes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e20 kits per case.\u003c\/p\u003e\u003ch3\u003eStellant service and troubleshooting\u003c\/h3\u003e\u003cp\u003eIf the injector itself is the problem rather than the consumables, our \u003ca href=\"\/pages\/stellant-error-codes\"\u003eStellant error code reference\u003c\/a\u003e names the faults and \u003ca href=\"\/pages\/medrad-stellant-troubleshooting\"\u003eStellant troubleshooting\u003c\/a\u003e covers the symptoms. We also do \u003ca href=\"\/pages\/stellant-preventive-maintenance\"\u003epreventive maintenance\u003c\/a\u003e and \u003ca href=\"\/pages\/stellant-injector-calibration-verification\"\u003ecalibration verification\u003c\/a\u003e on these units.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52268587843872,"sku":"100110","price":322.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/100110-kit.png?v=1788029626"},{"product_id":"stellant-single-syringe-kit-case-of-50","title":"Syringe Kit for Medrad Stellant CT Injector - 200 mL, Case of 50","description":"\u003cp\u003eSingle 200 mL contrast syringe kits for the Bayer Medrad Stellant CT injector. Replaces OEM part numbers \u003cstrong\u003eSSS-CTP-SPK\u003c\/strong\u003e and \u003cstrong\u003eSSS-CTP-QFT\u003c\/strong\u003e. Sold by the case of 50.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injector named above and replace the OEM part numbers listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x 200 mL syringe\u003c\/li\u003e\n\u003cli\u003e60 inch coiled tube with check valve\u003c\/li\u003e\n\u003cli\u003ePrime tube\u003c\/li\u003e\n\u003cli\u003eSpike or quick fill tube\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eStellant service and troubleshooting\u003c\/h3\u003e\u003cp\u003eIf the injector itself is the problem rather than the consumables, our \u003ca href=\"\/pages\/stellant-error-codes\"\u003eStellant error code reference\u003c\/a\u003e names the faults and \u003ca href=\"\/pages\/medrad-stellant-troubleshooting\"\u003eStellant troubleshooting\u003c\/a\u003e covers the symptoms. We also do \u003ca href=\"\/pages\/stellant-preventive-maintenance\"\u003epreventive maintenance\u003c\/a\u003e and \u003ca href=\"\/pages\/stellant-injector-calibration-verification\"\u003ecalibration verification\u003c\/a\u003e on these units.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52268588269856,"sku":"100102","price":413.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/100102-kit_19b49379-d06d-43c9-aa28-82fc6398463f.png?v=1788029593"},{"product_id":"spectris-syringe-kit-case-of-50","title":"Syringe Kit for Medrad Spectris Dual MRI Injector - 2 x 65 mL, Case of 50","description":"\u003cp\u003eContrast syringe kits for the original Bayer Medrad Spectris MRI injector. Replaces OEM part number \u003cstrong\u003eSQK 65VS\u003c\/strong\u003e. Sold by the case of 50. Discontinued by Bayer, still supplied by us.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injector named above and replace the OEM part number listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003cp\u003eBayer has published an end of life date of \u003cstrong\u003e12\/31\/2028\u003c\/strong\u003e for the Spectris Solaris EP. If you are running a legacy Spectris, consumable supply is the question worth planning around now. \u003ca href=\"\/pages\/bayer-injector-end-of-life\"\u003eRead what the end of life dates actually mean\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 x 65 mL syringes\u003c\/li\u003e\n\u003cli\u003e96 inch T coiled tubing\u003c\/li\u003e\n\u003cli\u003eLong and short spike\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eSpectris Solaris service and troubleshooting\u003c\/h3\u003e\u003cp\u003eWe supply these kits for the original Spectris. We do not service that platform. The injector we do service is the \u003cstrong\u003eSpectris Solaris\u003c\/strong\u003e, and if that is what you are running, \u003ca href=\"\/pages\/spectris-solaris-troubleshooting\"\u003eSpectris Solaris troubleshooting\u003c\/a\u003e covers the symptoms we see most, and we also do \u003ca href=\"\/pages\/spectris-solaris-preventive-maintenance\"\u003epreventive maintenance\u003c\/a\u003e and \u003ca href=\"\/pages\/spectris-solaris-calibration-verification\"\u003ecalibration verification\u003c\/a\u003e on the Spectris Solaris. Not sure which kit fits? The \u003ca href=\"\/pages\/injector-syringe-cross-reference\"\u003ecross reference\u003c\/a\u003e lists OEM part numbers against ours.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52268588532000,"sku":"100301","price":681.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/100301-kit.png?v=1788029699"},{"product_id":"spectris-solaris-syringe-kit-case-of-50","title":"Syringe Kit for Medrad Spectris Solaris MRI Injector - 65 and 115 mL, Case of 50","description":"\u003cp\u003eContrast syringe kits for the Bayer Medrad Spectris Solaris MRI injector, Solaris and Solaris EP. Replaces OEM part number \u003cstrong\u003eSSQK 65\/115VS\u003c\/strong\u003e (also written SSQK65VS and SSQK115VS). Sold by the case of 50.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injector named above and replace the OEM part numbers listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003cp\u003eBayer has published an end of life date of \u003cstrong\u003e12\/31\/2028\u003c\/strong\u003e for the Spectris Solaris EP. \u003ca href=\"\/pages\/bayer-injector-end-of-life\"\u003eRead what the end of life dates actually mean\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x 65 mL and 1 x 115 mL syringe\u003c\/li\u003e\n\u003cli\u003e96 inch T coiled tubing\u003c\/li\u003e\n\u003cli\u003eLong and short spike\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case, a contrast and saline pair.\u003c\/p\u003e\u003ch3\u003eSpectris service and troubleshooting\u003c\/h3\u003e\u003cp\u003eIf the injector itself is the problem, \u003ca href=\"\/pages\/spectris-solaris-troubleshooting\"\u003eSpectris Solaris troubleshooting\u003c\/a\u003e covers the symptoms we see most. We also do \u003ca href=\"\/pages\/spectris-solaris-preventive-maintenance\"\u003epreventive maintenance\u003c\/a\u003e and \u003ca href=\"\/pages\/spectris-solaris-calibration-verification\"\u003ecalibration verification\u003c\/a\u003e on these units. Not sure which kit fits? The \u003ca href=\"\/pages\/injector-syringe-cross-reference\"\u003ecross reference\u003c\/a\u003e lists OEM part numbers against ours.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52268588990752,"sku":"100302","price":671.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/100302-kit.png?v=1788029463"},{"product_id":"mark-7-arterion-syringe-kit-case-of-50","title":"Syringe Kit for Medrad Mark 7 Arterion Angiography Injector - 150 mL, Case of 50","description":"\u003cp\u003e150 mL contrast syringe kits for the Bayer Medrad \u003cstrong\u003eMark 7 Arterion\u003c\/strong\u003e angiographic injector. Replaces OEM part number \u003cstrong\u003eART 700 SYR\u003c\/strong\u003e. Sold by the case of 50.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injector named above and replace the OEM part number listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x 150 mL syringe\u003c\/li\u003e\n\u003cli\u003e1 x fill tube\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52279379886368,"sku":"100205","price":343.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/100205-kit_01100d53-56f9-4543-8c07-ae3fc459c4b2.png?v=1788122696"},{"product_id":"bracco-empowercta-dual-syringe-kit-case-of-20","title":"Dual Syringe Kit for Bracco EmpowerCTA CT Injector - 2 x 200 mL, Case of 20","description":"\u003cp\u003eDual contrast syringe kits for the \u003cstrong\u003eBracco EmpowerCTA\u003c\/strong\u003e and \u003cstrong\u003eEmpowerCTA+\u003c\/strong\u003e injector. Replaces OEM part numbers \u003cstrong\u003e017354\u003c\/strong\u003e and \u003cstrong\u003e017355\u003c\/strong\u003e. Sold by the case of 20.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injector named above and replace the OEM part numbers listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 x 200 mL syringes\u003c\/li\u003e\n\u003cli\u003e1 x 60 inch coiled tube with dual check valves\u003c\/li\u003e\n\u003cli\u003e2 x fill tubes\u003c\/li\u003e\n\u003cli\u003e2 x spikes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e20 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52279379919136,"sku":"400109","price":340.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/400109-kit_2de837d2-ce70-4275-a866-6049e826c02c.png?v=1788122610"},{"product_id":"envision-vistron-syringe-kit-case-of-50","title":"Syringe Kit for Medrad EnVision and Vistron CT Injectors - 200 mL, Case of 50","description":"\u003cp\u003e200 mL contrast syringe kits for the Bayer Medrad \u003cstrong\u003eEnVision\u003c\/strong\u003e and \u003cstrong\u003eVistron CT\u003c\/strong\u003e injectors. Replaces OEM part number \u003cstrong\u003eCTP-200-FLS\u003c\/strong\u003e. Sold by the case of 50. Discontinued by Bayer, still supplied by us.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injectors named above and replace the OEM part number listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003cp\u003eBayer ended support for the EnVision on 12\/31\/2023 and the Vistron on 12\/31\/2025, and no longer supplies the CTP-200-FLS kit. The injector still works. We still supply the kits. \u003ca href=\"\/pages\/bayer-injector-end-of-life\"\u003eRead what the end of life dates actually mean\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWhat do I do if I cannot get syringes from Bayer any more?\u003c\/h3\u003e\u003cp\u003eYou buy equivalent kits. Bayer has discontinued the CTP-200-FLS, SQK 65VS, 150-FT-Q and 200-FT-Q. We supply replacements for all four, by the case, shipped from the manufacturer's US warehouse. Tell us the part number on the box you used to order and we will tell you which of ours replaces it. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x 200 mL syringe\u003c\/li\u003e\n\u003cli\u003e1 x 60 inch coiled tube\u003c\/li\u003e\n\u003cli\u003e1 x fill tube\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52279379951904,"sku":"100101","price":391.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/100101-kit_35227073-9bf3-4c63-a2cf-0dbb0eff1293.png?v=1788122580"},{"product_id":"bracco-empowerct-syringe-kit-case-of-50","title":"Syringe Kit for Bracco EmpowerCT and EmpowerCTA CT Injectors - 200 mL, Case of 50","description":"\u003cp\u003eContrast syringe kits for the \u003cstrong\u003eBracco EmpowerCT\u003c\/strong\u003e and \u003cstrong\u003eEmpowerCTA\u003c\/strong\u003e injectors. Replaces OEM part numbers \u003cstrong\u003e017344\u003c\/strong\u003e and \u003cstrong\u003e017345\u003c\/strong\u003e. Sold by the case of 50.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injectors named above and replace the OEM part numbers listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x 200 mL syringe\u003c\/li\u003e\n\u003cli\u003e1 x 60 inch coiled tube\u003c\/li\u003e\n\u003cli\u003e1 x fill tube\u003c\/li\u003e\n\u003cli\u003e1 x spike\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52279379984672,"sku":"400101","price":366.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/400101-kit_386e61a3-e171-42c0-8124-9505542359b8.png?v=1788122506"},{"product_id":"mark-v-provis-syringe-kit-case-of-50","title":"Syringe Kit for Medrad Mark V and ProVis Angiography Injectors - 150 mL, Case of 50","description":"\u003cp\u003eContrast syringe kits for the Bayer Medrad \u003cstrong\u003eMark V\u003c\/strong\u003e and \u003cstrong\u003eMark V ProVis\u003c\/strong\u003e injectors. Replaces OEM part number \u003cstrong\u003e150-FT-Q\u003c\/strong\u003e. Sold by the case of 50. Discontinued by Bayer, still supplied by us.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injectors named above and replace the OEM part number listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003cp\u003eBayer ended support for the Mark V ProVis on 12\/31\/2025 and for the Mark V and Mark V Plus on 12\/31\/2020, and no longer supplies the 150-FT-Q kit. The injector still works. We still supply the kits. \u003ca href=\"\/pages\/bayer-injector-end-of-life\"\u003eRead what the end of life dates actually mean\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWhat do I do if I cannot get syringes from Bayer any more?\u003c\/h3\u003e\u003cp\u003eYou buy equivalent kits. Bayer has discontinued the CTP-200-FLS, SQK 65VS, 150-FT-Q and 200-FT-Q. We supply replacements for all four, by the case, shipped from the manufacturer's US warehouse. Tell us the part number on the box you used to order and we will tell you which of ours replaces it. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x 150 mL syringe\u003c\/li\u003e\n\u003cli\u003e1 x fill tube\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52279380017440,"sku":"100201","price":273.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/100201-kit_074533ef-fa12-472c-b67d-cea99c2e427b.png?v=1788122456"},{"product_id":"mark-v-provis-200ml-syringe-kit-case-of-50","title":"Syringe Kit for Medrad Mark V and ProVis Angiography Injectors - 200 mL, Case of 50","description":"\u003cp\u003eContrast syringe kits for the Bayer Medrad \u003cstrong\u003eMark V\u003c\/strong\u003e and \u003cstrong\u003eMark V ProVis\u003c\/strong\u003e injectors. Replaces OEM part number \u003cstrong\u003e200-FT-Q\u003c\/strong\u003e. Sold by the case of 50. Discontinued by Bayer, still supplied by us.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injectors named above and replace the OEM part number listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003cp\u003eBayer ended support for the Mark V ProVis on 12\/31\/2025 and for the Mark V and Mark V Plus on 12\/31\/2020, and no longer supplies the 200-FT-Q kit. The injector still works. We still supply the kits. \u003ca href=\"\/pages\/bayer-injector-end-of-life\"\u003eRead what the end of life dates actually mean\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWhat do I do if I cannot get syringes from Bayer any more?\u003c\/h3\u003e\u003cp\u003eYou buy equivalent kits. Bayer has discontinued the CTP-200-FLS, SQK 65VS, 150-FT-Q and 200-FT-Q. We supply replacements for all four, by the case, shipped from the manufacturer's US warehouse. Tell us the part number on the box you used to order and we will tell you which of ours replaces it. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x 200 mL syringe\u003c\/li\u003e\n\u003cli\u003e1 x fill tube\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52358094422304,"sku":"100202","price":357.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/100202-kit.png?v=1789485384"},{"product_id":"ct9000-optione-125ml-syringe-kit-case-of-50","title":"Syringe Kit for Mallinckrodt CT9000 and OptiOne CT Injectors - 125 mL, Case of 50","description":"\u003cp\u003eContrast syringe kits for the Mallinckrodt \u003cstrong\u003eCT9000\u003c\/strong\u003e, \u003cstrong\u003eCT9000 ADV\u003c\/strong\u003e and \u003cstrong\u003eOptiOne with Adapter\u003c\/strong\u003e CT injectors. Single 125 mL syringe kit. Sold by the case of 50.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. This one is a purpose-built configuration for these injectors rather than a copy of an OEM part, so there is no OEM part number to cross-reference against it.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x 125 mL syringe\u003c\/li\u003e\n\u003cli\u003e1 x 60 inch coiled tube\u003c\/li\u003e\n\u003cli\u003e1 x fill tube\u003c\/li\u003e\n\u003cli\u003e1 x spike\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52358094520608,"sku":"200111","price":378.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/200111-kit.png?v=1789485384"},{"product_id":"optivantage-dual-125ml-syringe-kit-case-of-20","title":"Dual Syringe Kit for Mallinckrodt OptiVantage DH CT Injector - 2 x 125 mL, Case of 20","description":"\u003cp\u003eDual contrast syringe kits for the Mallinckrodt \u003cstrong\u003eOptiVantage DH with Adapters\u003c\/strong\u003e CT injector. Sold by the case of 20.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. This one is a purpose-built configuration for the OptiVantage DH rather than a copy of an OEM part, so there is no OEM part number to cross-reference against it.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 x 125 mL syringes\u003c\/li\u003e\n\u003cli\u003e1 x 60 inch coiled tube with dual check valves\u003c\/li\u003e\n\u003cli\u003e2 x spikes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e20 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52358094618912,"sku":"200113","price":391.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/200113-kit.png?v=1789485384"},{"product_id":"optistar-dual-60ml-syringe-kit-case-of-50","title":"Dual Syringe Kit for Mallinckrodt Optistar MRI Injector - 2 x 60 mL, Case of 50","description":"\u003cp\u003eContrast syringe kits for the Mallinckrodt \u003cstrong\u003eOptiStar LE\u003c\/strong\u003e and \u003cstrong\u003eOptiStar Elite\u003c\/strong\u003e MRI injectors. Replaces OEM part number \u003cstrong\u003e801800B\u003c\/strong\u003e. Sold by the case of 50.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injectors named above and replace the OEM part number listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 x 60 mL syringes\u003c\/li\u003e\n\u003cli\u003e1 x 96 inch coiled tube with dual check valves\u003c\/li\u003e\n\u003cli\u003e2 x spikes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52358094684448,"sku":"200301","price":752.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/200301-kit.png?v=1789485384"},{"product_id":"optistar-60ml-syringe-kit-case-of-50","title":"Syringe Kit for Mallinckrodt Optistar MRI Injector - 60 mL, Case of 50","description":"\u003cp\u003eContrast syringe kits for the Mallinckrodt \u003cstrong\u003eOptiStar LE\u003c\/strong\u003e and \u003cstrong\u003eOptiStar Elite\u003c\/strong\u003e MRI injectors. Replaces OEM part number \u003cstrong\u003e801801B\u003c\/strong\u003e. Sold by the case of 50.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injectors named above and replace the OEM part number listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x 60 mL syringe\u003c\/li\u003e\n\u003cli\u003e1 x 96 inch coiled tube with dual check valves\u003c\/li\u003e\n\u003cli\u003e1 x spike\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52358094782752,"sku":"200301A","price":505.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/200301A-kit.png?v=1789485384"},{"product_id":"ct9000-optione-200ml-syringe-kit-case-of-50","title":"Syringe Kit for Mallinckrodt CT9000 and OptiOne CT Injectors - 200 mL, Case of 50","description":"\u003cp\u003eContrast syringe kits for the Mallinckrodt \u003cstrong\u003eCT9000\u003c\/strong\u003e, \u003cstrong\u003eCT9000 ADV\u003c\/strong\u003e and \u003cstrong\u003eOptiOne\u003c\/strong\u003e CT injectors. Replaces OEM part numbers \u003cstrong\u003e800099S\u003c\/strong\u003e, \u003cstrong\u003e800096S\u003c\/strong\u003e and \u003cstrong\u003e844021S\u003c\/strong\u003e. Sold by the case of 50.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injectors named above and replace the OEM part numbers listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x 200 mL syringe\u003c\/li\u003e\n\u003cli\u003e1 x 60 inch coiled tube\u003c\/li\u003e\n\u003cli\u003e1 x fill tube\u003c\/li\u003e\n\u003cli\u003e1 x spike\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52358900777248,"sku":"200101","price":462.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/200101-kit.png?v=1789486517"},{"product_id":"angiomat-6000-150ml-syringe-kit-case-of-50","title":"Syringe Kit for Mallinckrodt Angiomat 6000 Angiography Injector - 150 mL, Case of 50","description":"\u003cp\u003eContrast syringe kits for the Mallinckrodt \u003cstrong\u003eAngiomat 6000\u003c\/strong\u003e and \u003cstrong\u003eAngiomat Illumena with Adapter\u003c\/strong\u003e DSA injectors. Replaces OEM part numbers \u003cstrong\u003e600269\u003c\/strong\u003e and \u003cstrong\u003e900103S\u003c\/strong\u003e. Sold by the case of 50.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injectors named above and replace the OEM part numbers listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1 x 150 mL syringe\u003c\/li\u003e\n\u003cli\u003e1 x fill tube\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003cp\u003eThe Angiomat Illumena requires a pressure jacket. Call 615-479-5572 if you are not sure which you have.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52358900810016,"sku":"200201","price":365.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/200201-kit.png?v=1789486517"},{"product_id":"ct-injector-coiled-connecting-tubing-150-cm-case-of-200","title":"CT Injector Coiled Connecting Tubing - 150 cm, Case of 200","description":"\u003cp\u003eCoiled connecting tubing for CT power injectors, 150 cm (60 inch), sterile and single use. Cross references the Bayer \/ Medrad 60 inch patient tubing used on EnVision, Vistron and other legacy CT injectors, including catalog LPDCT 160.\u003c\/p\u003e\u003cp\u003eAlso cross references Guerbet 601195 (Optivantage) and Bracco 100113 (EmpowerCTA).\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUnit of measure: case (CS) of 200. Bayer sold LPDCT 160 50 to a box, so one case replaces four boxes. Compare price per piece, not per box.\u003c\/li\u003e\n\u003cli\u003eLength: 150 cm (60 in) coiled\u003c\/li\u003e\n\u003cli\u003eSterile, single use\u003c\/li\u003e\n\u003cli\u003ePrice includes shipping in the continental US\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNot sure this is the right tubing for your injector? Send the part number off the box you run today and we will confirm before you order.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Case of 200","offer_id":52456386822432,"sku":"600150","price":269.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/600150-ct-coiled-connecting-tubing-150cm.jpg?v=1790874421"},{"product_id":"ct-injector-y-line-tubing-60-inch-2-check-valves-case-of-200","title":"CT Injector Y-Line Tubing - 60 inch, 2 Check Valves, Case of 200","description":"\u003cp\u003eY-line connecting tubing for CT power injectors, 60 inch (150 cm), with two check valves. Sterile, single use. Used for dual-head CT injection where contrast and saline share one patient line.\u003c\/p\u003e\u003cp\u003eCross references Guerbet 844012 and 240002B (Optivantage).\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUnit of measure: case (CS) of 200. OEM tubing is often boxed in smaller counts, so check the count on the box you buy today and compare price per piece.\u003c\/li\u003e\n\u003cli\u003eLength: 60 in (150 cm)\u003c\/li\u003e\n\u003cli\u003eTwo check valves\u003c\/li\u003e\n\u003cli\u003eSterile, single use\u003c\/li\u003e\n\u003cli\u003ePrice includes shipping in the continental US\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSend the part number off the box you run today and we will confirm the cross reference before you order.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":52456387543328,"sku":"614150","price":535.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/614150-ct-y-line-tubing-60in-2-check-valves.jpg?v=1790874421"},{"product_id":"mri-injector-y-line-tubing-96-inch-2-check-valves-case-of-200","title":"MRI Injector Y-Line Tubing - 96 inch, 2 Check Valves, Case of 200","description":"\u003cp\u003eY-line connecting tubing for MRI power injectors, 96 inch, with two check valves. Sterile, single use. The longer 96 inch run is what MRI suites need to reach the bore from the injector.\u003c\/p\u003e\u003cp\u003eCross references Guerbet 801107B and 240005B (Optistar Elite and Optistar LE).\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUnit of measure: case (CS) of 200. OEM tubing is often boxed in smaller counts, so check the count on the box you buy today and compare price per piece.\u003c\/li\u003e\n\u003cli\u003eLength: 96 in\u003c\/li\u003e\n\u003cli\u003eTwo check valves\u003c\/li\u003e\n\u003cli\u003eSterile, single use\u003c\/li\u003e\n\u003cli\u003ePrice includes shipping in the continental US\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSend the part number off the box you run today and we will confirm the cross reference before you order.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Case of 200","offer_id":52456388591904,"sku":"614250","price":609.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/614250-mri-y-line-tubing-96in-2-check-valves.jpg?v=1790874421"},{"product_id":"injector-transfer-set-50-cm-long-spike-swabable-valve-case-of-200","title":"Injector Transfer Set - 50 cm, Long Spike, Swabable Valve, Case of 200","description":"\u003cp\u003eTransfer set for power injector filling, 50 cm, with a long spike and a swabable valve. Sterile, single use. Used to draw contrast or saline from the bottle into the syringe.\u003c\/p\u003e\u003cp\u003eCross references Merit TS-220.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUnit of measure: case (CS) of 200. OEM tubing is often boxed in smaller counts, so check the count on the box you buy today and compare price per piece.\u003c\/li\u003e\n\u003cli\u003eLength: 50 cm\u003c\/li\u003e\n\u003cli\u003eLong spike, swabable valve\u003c\/li\u003e\n\u003cli\u003eSterile, single use\u003c\/li\u003e\n\u003cli\u003ePrice includes shipping in the continental US\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSend the part number off the box you run today and we will confirm the cross reference before you order.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Case of 200","offer_id":52456389017888,"sku":"630050","price":669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/630050-injector-transfer-set-50cm.png?v=1790874422"},{"product_id":"high-pressure-braided-injector-tubing-72-inch-rotating-adapter-case-of-200","title":"High-Pressure Braided Injector Tubing - 72 inch, Rotating Adapter, Case of 200","description":"\u003cp\u003eHigh-pressure braided connecting tubing, 72 inch, with a rotating adapter. Sterile, single use. Built for the injection pressures used in angiography and cardiac work, where standard coiled tubing is not rated.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUnit of measure: case (CS) of 200. OEM tubing is often boxed in smaller counts, so check the count on the box you buy today and compare price per piece.\u003c\/li\u003e\n\u003cli\u003eLength: 72 in\u003c\/li\u003e\n\u003cli\u003eBraided high-pressure line, rotating adapter\u003c\/li\u003e\n\u003cli\u003eSterile, single use\u003c\/li\u003e\n\u003cli\u003ePrice includes shipping in the continental US\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSend the part number off the box you run today and we will confirm the cross reference and the pressure rating before you order.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Case of 200","offer_id":52456389443872,"sku":"HBR180","price":885.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/hbr180-high-pressure-braided-tubing-72in.jpg?v=1790874421"},{"product_id":"bracco-empowermr-dual-syringe-kit-case-of-50","title":"Dual Syringe Kit for Bracco EmpowerMR Injector - 2 x 100 mL, Case of 50","description":"\u003cp\u003eDual contrast syringe kits for the \u003cstrong\u003eBracco EmpowerMR\u003c\/strong\u003e MRI injector, originally sold as the E-Z-EM EmpowerMR. Replaces OEM part numbers \u003cstrong\u003e017356\u003c\/strong\u003e and \u003cstrong\u003e017348\u003c\/strong\u003e. Sold by the case of 50.\u003c\/p\u003e\u003ch3\u003eWhat these are, and shelf life\u003c\/h3\u003e\u003cp\u003eThese are equivalent replacement kits, not OEM product. They fit the injector named above and replace the OEM part numbers listed.\u003c\/p\u003e\u003cp\u003eThese ship from the manufacturer's US warehouse rather than a reseller's back stock, so you are not buying something that has been sitting. The cases we have shipped have carried more than three years of remaining shelf life.\u003c\/p\u003e\u003ch3\u003eWhat is in each kit\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e2 x 100 mL syringes\u003c\/li\u003e\n\u003cli\u003e1 x 96 inch Y coiled tube with dual check valves\u003c\/li\u003e\n\u003cli\u003e1 x long spike\u003c\/li\u003e\n\u003cli\u003e1 x short spike\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e50 kits per case.\u003c\/p\u003e\u003ch3\u003eShipping and lead time\u003c\/h3\u003e\u003cp\u003ePrice includes shipping to the continental United States. Ships in 1 to 2 business days. Tracking follows by email.\u003c\/p\u003e\u003cp\u003eNeed it faster than that? Call 615-479-5572 before you order.\u003c\/p\u003e\u003ch3\u003eTry one before you commit to a case\u003c\/h3\u003e\u003cp\u003eThese are sterile single-use kits, so once a case is opened it cannot be returned or restocked. That is true of every supplier, us included. Which is why we send a sample. We would rather put a kit in your hands and let it make the case. Run it on your own injector, then order once you know what you are getting. Call 615-479-5572 or use the quote form.\u003c\/p\u003e\u003ch3\u003eOrdering more than 5 cases\u003c\/h3\u003e\u003cp\u003eAsk for a freight-consolidated quote. Call 615-479-5572 or use the quote form and tell us the injector model, the part number you run today, and how many cases you go through in a year.\u003c\/p\u003e\u003ch3\u003eReturns\u003c\/h3\u003e\u003cp\u003eOpen a case and it is yours. These are sterile single-use medical devices and no supplier takes those back, us included. Unopened is different: send it back inside 30 days and we keep 20%. And if we shipped the wrong kit for your injector, that is our mistake, not yours. We replace it at our cost.\u003c\/p\u003e","brand":"FDM Enterprises","offers":[{"title":"Default Title","offer_id":67625242558752,"sku":"400302D","price":630.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/2778\/5248\/files\/400302D-kit.png?v=1790875749"}],"url":"https:\/\/fdmenterprises.com\/collections\/injector-consumables.oembed","provider":"FDM Enterprises","version":"1.0","type":"link"}